SUMMARY OF EQUIPMENT DELIVERED
SAC No. |
Date: |
17.01.2008 |
|
|
Project: |
CEC Runcu |
|
|
|
Site name: |
CR0309 |
|||
Site address: |
Arcani |
|||
Installer: |
Marius Motroc |
# |
Description |
Qty |
CONFORMANT |
CRITICALITY |
||
Y |
N |
Maj |
Min |
|||
1 |
DESKTOP CN4 2-SLOTS |
1 |
X |
- |
- |
- |
2 |
CROCUS ADM 2P CV BU |
1 |
X |
- |
- |
- |
3 |
ROUTER INTF. 10M CROCUS |
1 |
X |
- |
- |
- |
CARDNEST
Please check or fill the blank fields according to the delivery. The form shall contain information about only one cardnest.
TYPE |
CN4/2slots |
CN4/4slots |
CN4/15slots |
|||
P/N |
167992 |
163459 |
142189 |
|||
Delivered |
DESKTOP CN4 2-SLOTS | |||||
Cardnest ID |
S/N |
Hard. Rev. |
Rack Address (0..6) |
|||
PCB |
BA# |
|||||
S0159847 | ||||||
PWR #1 |
80W P/N 142190 |
300W P/N 143678 |
S/N |
Hard.Rev. 17517m126r |
|
|
PCB | ||||||
PWR #2 |
80W P/N 142190 |
300W P/N 143678 |
S/N |
Hard.Rev. 17517m126r | ||
PCB | ||||||
Please fill the following fields with OK, NOK, NA (for Not Applicable), or NT (for Not Tested). Use NT only on site.
Item |
STATUS |
|||||||||||||||
PWR #1 Redund. (2.2.3) | ||||||||||||||||
COMMENTS | ||||||||||||||||
PWR #2 Redund. (2.2.3) | ||||||||||||||||
COMMENTS | ||||||||||||||||
Alarm Contacts |
Power Fail Alarm (2.2.3) |
High Alarm (2.4.3.1-2) |
Low alarm (2.4.3.1-2) |
|||||||||||||
COMMENTS | ||||||||||||||||
CN4 Address*) (2.5.3.1) | ||||||||||||||||
COMMENTS | ||||||||||||||||
Cardnest Slot HS BUS (2.5.3.2) |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
||
COMMENTS | ||||||||||||||||
*) For daisy-chained CN4 cardnests
VERDICT
CONFORMANT |
CRITICALITY |
||
Y |
N |
Maj |
Min |
X |
- |
- |
- |
DATE |
TEST LOCATION |
PERSON |
COMPANY |
SIGNATURE |
|
SIGNATURE |
|
PERSON |
DEPT. | ||||||
17.01.2008 |
CR0309 |
Marius Motroc |
Radcom | ||||
Appendix B DXC CARD
Please check or fill the blank fields according to the delivery and installation. The form shall contain information about only one card.
TYPE |
DXC8 |
DXC16 | ||
P/N |
167322 |
167323 |
||
Delivered | ||||
Card ID |
S/N |
Hard. Rev. |
Rack# / Slot# |
|
PCB |
BA# |
|||
Software |
Boot Software |
Flash 1 |
Flash 2 |
|
Config |
SysName |
CMS Address |
IP Address |
|
Orchid ObjectTable Name SysName) |
Controlled by Orchid (name) |
Uplink to Orchid (HS/CTRL/TS0) |
||
Upstream DMM port (1..16/CTRL) |
Upstream DMM site | |||
Downstream DMM ports (1..16/CTRL) |
Downstream DMM sites |
|||
Please fill the following fields with OK, NOK, NA (for Not Applicable), or NT (for Not Tested). Use NT only on site.
Item |
STATUS |
|||||||||
E1 Port OK? (2.4.3.1) |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
||
COMMENTS | ||||||||||
LEDs OK? (2.4.3.1) |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
||
COMMENTS | ||||||||||
E1 Port OK? (2.4.3.1) |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
||
COMMENTS | ||||||||||
LEDs OK? (2.4.3.1) |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
||
| ||||||||||
COMMENTS | ||||||||||
Alarms |
High Alarm (2.4.3.1-2) |
Low alarm (2.4.3.1-2) |
HS BUS & NMS (2.5.3.2-6) |
|||||||
COMMENTS | ||||||||||
VERDICT
CONFORMANT |
CRITICALITY |
||
Y |
N |
Maj |
Min |
DATE |
TEST LOCATION |
PERSON |
COMPANY |
SIGNATURE |
|
SIGNATURE |
|
PERSON |
DEPT. | ||||||
Appendix B ADM2P & CNV CARDS
Please check or fill the blank fields according to the delivery and installation. The form shall contain information about only one card.
TYPE |
ADM2P |
CNV Nx64 | ||||||
P/N |
171294 |
171291 |
||||||
Delivered |
CROCUS ADM 2P CV BU | |||||||
Card ID |
S/N |
Hard. Rev. |
Rack# / Slot# |
|||||
PCB |
BA# |
|||||||
S0159847 | ||||||||
Software |
Boot Software |
Flash 1 |
Flash 2 |
|||||
T2770/00100 23/07/01 |
T2771/01700 25/04/06 |
T2771/01600 22/12/04 |
||||||
Module A |
TYPE |
P/N |
S/N |
Hard. Rev. |
MAC Addr. |
|||
PCB |
BA# |
|||||||
ROUTER INTF. 10M CROCUS |
40992775 |
00C0890f2607 |
||||||
Boot Software |
Flash 1 |
Flash 2 |
||||||
T2850/00300 26/01/24 |
T2852/03300 23/11/06 |
T2852/02800 24/05/05 |
||||||
SysName |
IP Address/Protocol (LAN) |
IP Address/Protocol (WAN) |
||||||
CR309R1001 |
172.28.10.190 |
172.28.11.126 |
||||||
Module B |
TYPE |
P/N |
S/N |
Hard. Rev. |
MAC Addr. |
|||
PCB |
BA# |
|||||||
Boot Software |
Flash 1 |
Flash 2 |
||||||
SysName |
IP Address/Protocol (LAN) |
IP Address/Protocol (WAN) |
||||||
Config |
SysName |
CMS Address |
IP Address |
|||||
CR309A2P01 | ||||||||
Orchid ObjectTable Name SysName) |
Controlled by Orchid (name) |
Uplink to Orchid (HS/CTRL/TS0) |
||||||
Upstream DMM port (1..16/CTRL) |
Upstream DMM site | |||||||
Downstream DMM ports (1..16/CTRL) |
Downstream DMM sites |
|||||||
Please fill the following fields with OK, NOK, NA (for Not Applicable), or NT (for Not Tested). Use NT only on site.
Item |
STATUS |
||||
E1 Port OK? (2.4.3.1) |
E1A |
E1B | |||
OK | |||||
COMMENTS | |||||
LEDs OK? (2.4.3.1) |
E1A |
E1B | |||
OK | |||||
COMMENTS | |||||
Module OK? (2.4.3.2-2.4.3.3) |
A |
B |
|||
OK | |||||
COMMENTS | |||||
LEDs OK? (2.4.3.2-2.4.3.3) |
A |
B |
|||
OK | |||||
COMMENTS | |||||
Alarms |
High Alarm (2.4.3.1-2) |
Low alarm (2.4.3.1-2) |
HS BUS & NMS (2.5.3.2-6) |
||
OK |
OK |
OK |
|||
COMMENTS | |||||
Appendix B ADM2P & CNV CARDS
(Page 2)
VERDICT
CONFORMANT |
CRITICALITY |
||
Y |
N |
Maj |
Min |
X |
- |
- |
- |
DATE |
TEST LOCATION |
PERSON |
COMPANY |
SIGNATURE |
|
SIGNATURE |
|
PERSON |
DEPT. | ||||||
17.01.2008 |
CR309 |
Marius Motroc |
Radcom | ||||
| |||||||
Appendix B ORCHID 1003 LAN CARDS
Please check or fill the blank fields according to the delivery and installation. The form shall contain information about only one card.
Card ID |
S/N |
Hard. Rev. |
MAC Address |
|
PCB |
BA# |
|||
Software |
Boot Software |
Flash 1 |
Flash 2 |
|
Config |
SysName |
HS Bus Speed / Max. Speed |
IP Addr. TPI |
|
IP Addr. / Protocol Port A |
IP Addr. / Protocol Port B |
Port 1 protocol (cms/nms) |
||
Neighbor Port A |
Neighbor Port B |
Port 2 protocol (cms/nms) |
||
Neighbor TPI |
Sites managed over DMM |
|||
Please fill the following fields with OK, NOK, NA (for Not Applicable), or NT (for Not Tested). Use NT only on site.
Item |
STATUS |
|||||
Port OK? (2.5.3.3) |
1 |
2 |
A |
B |
||
COMMENTS | ||||||
Port/Resource OK? (2.5.3.3-5) |
TPI |
HS |
DMM |
Flash System |
||
COMMENTS | ||||||
Alarms |
High Alarm (2.4.3.1-2) |
Low alarm (2.4.3.1-2) |
HS BUS & NMS (2.5.3.2-6) |
|||
COMMENTS | ||||||
VERDICT
CONFORMANT |
CRITICALITY |
||
Y |
N |
Maj |
Min |
DATE |
TEST LOCATION |
PERSON |
COMPANY |
SIGNATURE |
|
SIGNATURE |
|
PERSON |
DEPT. | ||||||
INSTALLATION, COMMISSIONING AND INTEGRATION
SAC No. |
Date: |
17.01.2008 |
|
Project: |
CEC Runcu |
| |
Site name: |
CR309 |
||
Site address: |
Arcani |
||
Installer: |
Marius Motroc |
Objective |
STATUS (OK/NOK) |
Cabling to DDF |
OK |
COMMENTS | |
Intrashelf cabling |
OK |
COMMENTS | |
Intershelf cabling |
OK |
COMMENTS | |
Power supply cabling |
OK |
COMMENTS | |
Safety Rules |
OK |
COMMENTS | |
Earthing |
OK |
COMMENTS | |
Marking and Labelling |
OK |
COMMENTS | |
Final Config. (2.6.1) |
OK |
COMMENTS | |
Alarms (2.6.1) |
OK |
COMMENTS | |
Integration - NMS (2.5.4) |
OK |
COMMENTS | |
Transmission links (2.7.1) |
OK |
COMMENTS/RESULTS | |
Cleanliness of site |
OK |
COMMENTS |
VERDICT
CONFORMANT |
CRITICALITY |
||
Y |
N |
Maj |
Min |
X |
- |
- |
- |
DATE |
TEST LOCATION |
PERSON |
COMPANY |
SIGNATURE |
|
SIGNATURE |
|
PERSON |
DEPT. | ||||||
17.01.2008 |
CR0309 |
Marius Motroc |
Radcom | ||||
END OF DOCUMENT
|