Cond. bran. |
l |
E1 |
E2 |
E |
dn |
wcb |
icb |
∑ξcb |
hloc.ap |
icb*lcb |
qc |
hloc.tot |
hrcb |
990(R+L+B)+990S |
E=E1+E2
qc=b(a*c√E+0.004E)
a=0.15
b=1
qc=0.15√E+0.004E
lcb=15 m
ξcb=0.042
5 robinete 6
2 coturi 1
3 teuri trecere 0.5
1 ingustare de sectiune 0.5
1 marire de sectiune 0.3
hloc. ap=0.045 bar=0.45 m H2O
hr loc tot=hr loc ap+Σ cb*Wcb/(2*g)*1000=0.45+34.3*1.092*1000/(2*10)= =2038.0415
hr cb=icb*lcb+hloc tot=7.5*15+2038.0415=2.15054 mH2O
Dimensionarea rezervoarelor tampon si a instalatiilor hidraulice anexe:
VURT=150(Gp+10) => tipul rezervorului
Gp>qc =>VURT=150(22+10)=150*32=4800≈5000
qc=19.476 =>Gp=22
Aleg rezervor tip B, model 3, capacitate 5000l.
hURT=VURT/(l*b)=5000/(2000*1250)= 2 m
htot=hURT+(0.10.0.15)+(0.35.0.5)=0.10+0.40+2=2.55 m
l*b*htot=2000*1250*2550 [mm]
Hdisp=HgRF+HURF+hrcb
HURF=Hdisp-(HgRF+hrcb)
Hdisp=27.6 mH2O
HgRF=1.2+0.3+0.5+0.15+2+0.4/2=4.35
HURF=27.6-6.45=21.15 mH2O
d1=D1/√N=150/√4=75 mm =>d1=80 mm
D2=150*2=300 mm (constructiv)
V1=√(2*g*hu)/(1+ξr)= √2*10*4.35/1=9.2737 m/s
HgRF=Hu=hu=4.35 m
ξr=0
D3==0.2458m *1000=
=245.832 mm
Ø 278*8 = >D3=278-2*8=262 mm
D3=262 mm
Vas prea plin, de forma tronconica, cu dimensiunile:
Dsup=600 mm
Dinf=300 mm
h= 600 mm
D4=d1*
ξ0=ξ1=3, ξr=0
D4=0.08
Ø 219*5 =>D4=209 mm
D5=d1*
ξr=0
h2=2 m
D5=0.08*=0.170654 m=170.654 mm
=>Ø 194*5 =>D5=184 mm
D4=D5=209 => Ø 219*5
H*=0.4+0.5+0.10+2=3 m
q=3.14*d12*V1/4=3.14*0.082*9.2736/4=0.046882 m3/s=46.882 l/s
=>D4=250 mm
i=4
l5=5 m
l=l4+l5=2+5=7 m
hr=i*l=4*7=28 mmH2O =0.028 mH2O
1 iesire 1*0.5=0.5
3 imbinari cu mufe 3*0.25=0.75
=>
Hp=34
Hi=Hp-3=31
H0=Hp+12
H0=46
Gpp=102
Gp0=46
Gpm=(Gpp+Gp0)/2
Gpm=74
VRH=1.1[Gpm*(Hp+10)*(H0+10)]/[4*n*(H0-Hp)*(Hi+10)]
VRH=6.749
Aleg 2 rezervoare hidrofor cu capacitatea de 4000l (4m3)
VRHreal=8
nreal=1.1[Gpm*(Hp+10)*(H0+10)]/[4*VRHreal*(H0-Hp)*(Hi+10)]
nreal=12.739
Avem 13 porniri pe ora.
Vumax=Gpm/(4*nreal)=1.452
h3=0.09
h4=0.490
humax=VRHreal/[2*(p*D2/4)]=3.537
Np=h3+h4+0.08=0.66
NRT=2.6
Hg0=N0-NRT=1.597
Hgp=Np-NRT=-1.94
ipp=21
vpp=1.8
ip0=37
vp0=2.4
l=10
Sxpp=35
Sxpo=16.5
hrlp=Sxpp*[vpp^2/(2*10)]=5.67
hrlo=Sxpo*[vpo^2/(2*10)]=4.752
hrp=ipp*(1/1000)+hrlp=5.88
hro=ipo*(1/1000)+hrlo=5.122
Hpp=Hp+Hgp+hrp=37.94
Hpo=Ho+Hgo+hrpo=52.719
Pompa aleasa este Lotru 100 F192
|